Accident Summary Nr: 201924438 - Explosion Kills One Employee, Injures Six Others
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311957187 | 06/11/2008 | 1799 | 238990 | Performance Insulation Contractors, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 311957161 | 06/11/2008 | 2822 | 325212 | Goodyear Tire & Rubber Houston Chemical Plant |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 311957187 | 06/11/2008 | 1799 | 238990 | Performance Insulation Contractors, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 311957195 | 06/11/2008 | 7349 | 561790 | Debusk Industrial Services Company (Disc) |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 311957179 | 06/11/2008 | 1629 | 237990 | Qualitech Maintenance, Inc. |
Abstract: At approximately 7:10 a.m. on June 11, 2008, Operators at the C2 unit (Plant 2) in C building were injecting 60-psi steam at a temperature of approximately 400-degrees Fahrenheit into a precooler, heat exchanger Model Number E300-G, to purge the process of the latex products. Latex was on the tube side and ammonia was on the shell side. The steam was injected into the tubes heating the ammonia on the shell side. The precooler over pressured, rupturing the shell, releasing ammonia into the environment. Employee #1 was found dead beneath the debris in the area of the heat exchanger several hours after the explosion occurred. Five contracted employees were severely exposed to ammonia. Employees #2, #3, #4, and # 6 were hospitalized. Employee #5 received first aid and was released.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Manufacturing plant | Maintenance or repair | $500,000 to $1,000,000 | 1 | 10 | X | ||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 311957187 | Hospitalized injury | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
||
| 2 | 311957187 | Hospitalized injury | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
||
| 3 | 311957187 | Non Hospitalized injury | Other | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
||
| 4 | 311957161 | Fatality | Concussion | Supervisors, production occupations | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Fatality Cause: |
||
| 5 | 311957187 | Hospitalized injury | Other | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
||
| 6 | 311957195 | Hospitalized injury | Other | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
||
| 7 | 311957179 | Hospitalized injury | Other | Janitors and cleaners | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Temporary work (buildings, facilities) Fatality Cause: Asphyxiation/inhalation of toxic vapor |
Translate