Accident Summary Nr: 201924370 - Welder Is Killed in Fall While Cutting Out Pollution Pan

Accident Summary Nr: 201924370 -- Report ID: 0626700 -- Event Date: 01/28/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31026636601/28/20081389213112Frank'S Casing Crew & Rental Tools, Inc.

Abstract: At approximately 7:30 a.m. on January 28, 2008, Employee #1, a welder, was working to cut out a section of a pollution pan located in the subfloor of a Hercules 251 Rig. The four-sided pollution pan was attached to the walls of the subfloor with twelve flat iron braces approximately 0.375 in. thick by 5 in. wide by 8 in. long. Three braces were located on each side of the pollution pan. The braces on the east and west side of the pan had been removed previously. The welding supervisor directed Employee #1 and another welder to cut the three braces that remained in place on each of the north and south sides of the pan. The other welder cut the three braces on one side and then stepped out of the pan. As Employee #1 cut the last brace, the pollution pan fell. Employee #1 fell approximately 44 ft to the "Texas Deck" located below the rig, striking his head on the well head. He then fell another 62 ft through the gap between the well head and the Texas Deck and landed in water. Employee #1 was recovered via use of the rig's rescue capsule. He was killed.

Keywords: UNSECURED, WELDER, BRACE, DRILL RIG--NON-OIL, FALL, FALL PROTECTION, CONCUSSION, OIL RIG, WORK SURFACE, CUTTING AND BURNING
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction Alteration or rehabilitation $50,000 to $250,000 1 107 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310266366 Fatality Concussion Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 107 feet
Cause: Backfilling and compacting
Fatality Cause: Fall through opening (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.