Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201858800 - Employee Is Killed by Falling Clay

Accident Summary Nr: 201858800 -- Report ID: 0452110 -- Event Date: 02/23/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30958228602/24/20061796238290P.D. Automation, Inc.

Abstract: Employee #1, of P.D. Automation, was removing a piece of angle iron from the inside of a clay storage tank. Employee #1 struck the angle iron which loosened the clay that was stuck to the inside of the tank. The clay fell on Employee #1 and killed him.

Keywords: LUNG, MAINTENANCE, ASPHYXIATED, INSTALLING, STORAGE TANK, BRICK, STRUCK BY, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant New project or new addition $5,000,000 to $20,000,000 1 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 309582286 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior cladding
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.