Accident Summary Nr: 201857570 - Seve employees killed and nine injured in plant explosion

Accident Summary Nr: 201857570 -- Report ID: 0452110 -- Event Date: 02/20/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30591044002/20/20033714238120Cta Acoustics Inc

Abstract: At approximately 7:30 a.m. on February 20, 2003, Employees were beginning their shift and four production lines were prepared to run product. An explosion occurred in the area of the facility's production lines known as Lines 405, 403, 402 and 401, which produce a fiberglass-resin blend automotive insulation. The explosion damaged all lines with the most significant damage on Lines 405 and 403. Damage to the facility included blown out roof decking, and fire and blast damage to the dust collection system. The explosion and subsequent fires resulted in the injury of 45 Employees, 18 of which were hospitalized. Of the 18 Employees hospitalized, Employees # 1, 9, 10, 11, 15, 16, and 18 died. Employees # 2 through 8, 12 through 14, and 17 received first-, second-, and third-degree burns, as well as lacerations, smoke inhalation, and one knee fracture.

Keywords: BURN, KNEE, FRACTURE, DUST, EXPLOSIVE MIXING, FIRE, DUST COLLECTOR, EXPLOSION, LACERATION, SMOKE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305910440 Hospitalized injury Fracture Machinery maintenance occupations
2 305910440 Fatality Burn/Scald(Heat) Production inspectors, checkers and examiners
3 305910440 Fatality Burn/Scald(Heat) Mixing and blending machine operators
4 305910440 Fatality Burn/Scald(Heat) Occupation not reported
5 305910440 Hospitalized injury Burn/Scald(Heat) Occupation not reported
6 305910440 Hospitalized injury Burn/Scald(Heat) Occupation not reported
7 305910440 Hospitalized injury Burn/Scald(Heat) Occupation not reported
8 305910440 Fatality Burn/Scald(Heat) Occupation not reported
9 305910440 Fatality Burn/Scald(Heat) Occupation not reported
10 305910440 Hospitalized injury Burn/Scald(Heat) Occupation not reported
11 305910440 Fatality Burn/Scald(Heat) Occupation not reported
12 305910440 Hospitalized injury Burn/Scald(Heat) Mixing and blending machine operators
13 305910440 Fatality Burn/Scald(Heat) Management related occupations, n.e.c.
14 305910440 Hospitalized injury Burn/Scald(Heat) Mixing and blending machine operators
15 305910440 Hospitalized injury Burn/Scald(Heat) Miscellaneous machine operators, n.e.c.
16 305910440 Hospitalized injury Burn/Scald(Heat) Furnace, kiln and oven operators
17 305910440 Hospitalized injury Other Miscellaneous machine operators, n.e.c.
18 305910440 Hospitalized injury Other Electrical and electronic technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.