Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201856291 - Two employees are killed in fall when scaffold cable broke

Accident Summary Nr: 201856291 -- Report ID: 0452110 -- Event Date: 06/18/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30429428306/18/20021629236210The Currens Company, Inc.

Abstract: At approximately 6:30 a.m. on June 18, 2002, Employees #1 and #2 were working from a suspended work platform inside an empty 200,000-gallon-capacity water tank. They were parching the side walls of the tank in preparation for the application of an intermediate protective layer when a suspension cable on the scaffold broke. Employees #1 and #2 fell 27 ft to the bottom of the water tank and were killed.

Keywords: BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, TWO PT SUSP SCAFFOLD, FALL, ELEVATED WORK PLAT, PAINTER, WATER TANK
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Alteration or rehabilitation $50,000 to $250,000 40 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304294283 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 32 feet
Cause: Waterproofing
Fatality Cause: Fall from/with scaffold
2 304294283 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 32 feet
Cause: Waterproofing
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.