Inspection NrDate OpenedSICNAICSEstablishment Name
30316474306/22/200028690Arch Chemicals Inc

Abstract: An oil reserve pot for a turbine expander for a nitrogen plant became contaminated with liquid Oxygen and Nitrogen due to a leaking check valve and control valves. The oil in the machine became frozen and maintenance turned on oil heater which resulted in two explosions of the oil reserve. Employees #1-#7 were sent to the hospital. Employees #6 and #7 were hospitalized. Both employees suffered severe fractures of the legs, arm and hand, and one of the two employees also received second-and-third-degree burns from the oil and fire.

Keywords: BURN, OXYGEN, FRACTURE, FIRE, NITROGEN, EXPLOSION, LACERATION, ABRASION, CONCUSSION, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303164743 Non Hospitalized injury Bruise/Contus/Abras Electronic repairers, communica. & indus. equip.
2 303164743 Non Hospitalized injury Bruise/Contus/Abras Machine operators, not specified
3 303164743 Non Hospitalized injury Cut/Laceration Machine operators, not specified
4 303164743 Non Hospitalized injury Concussion Supervisors, production occupations
5 303164743 Non Hospitalized injury Other Supervisors, production occupations
6 303164743 Hospitalized injury Fracture Industrial machinery repairers
7 303164743 Hospitalized injury Fracture Electronic repairers, communica. & indus. equip.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.