Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201797644 - Employee Fractures Thumb, and Hand is Degloved in Rolls

Accident Summary Nr: 201797644 -- Report ID: 0950644 -- Event Date: 12/15/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
11982268212/22/20033365331524Alpase, Inc.

Abstract: At 7:55 a.m. on December 15, 2003, Employee #1 was working as a quality control inspector for Alpase, Inc., in Downey, CA. He and a coworker were using a Walco model number 805-76 wide film laminator, with serial number 03-9010-7386. This machine applies a film of PVC covering material to aluminum plates that weigh in the hundreds of pounds. The aluminum plates are 0.625 inches thick. The PVC film is on rolls. The rolls are somewhat soft and can run forward or backward. They can also run on automatic or by means of a foot pedal operating as a constant contact control device. Because the rolls turn slowly and run quietly in the context of a noisy shop, it is difficult to know if the rolls are turning or not. At the time of the accident, the rolls were running in reverse and in automatic mode. The distance from the opening of the rolls' guard to their nip point was 5 inches, and the width of the opening was 2.25 inches. Employee #1 and a coworker had just finished removing uneven aluminum plates from the feed table. The rolls were running in reverse to eject the last plate, which was on the bottom. That plate had initially been pushed into the rolls to make contact with the film and to prevent it and the other plates from rolling off the feed table. Removal of the bottom plate was necessary. As the last plate was removed, the PVC material was being pulled into the feed side. Employee #1 went to the exit side of the rolls to pull out the PVC material. His right hand was pulled into the rolls' nip point. He sustained a fractured right thumb and a soft tissue avulsion (degloving) of the right hand. He was transported to Saint Francis Hospital and then was transferred to Western Hand and Orthopedics. He was hospitalized.

Keywords: FRACTURE, DEGLOVED, THUMB, ROLLER--MACH/PART, SKIN, NIP POINT, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119822682 Hospitalized injury Fracture Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close