Accident Summary Nr: 201796943 - Employee injured when finger amputated in punch press

Accident Summary Nr: 201796943 -- Report ID: 0950644 -- Event Date: 06/11/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
12609089306/10/20033469332116Action Stamping

Abstract: At 8:30 a.m. on June 11, 2003, employees of Action Stamping, Inc. was engaged in the production of sheet metal products using equipment such as punch presses and press brakes. Employee #1 had worked at Action Stamping, Inc. for three months as a press operator. The machine involved in the accident is a 45-ton punch press, a Komatsu Model Number OBS45, Serial Number 1A4292. The machine point of operation device has a two-hand control. The two-hand control is mounted on a pedestal. The pedestal is placed in front of the press. The controls are located at approximately the same elevation as the die bolster. The pedestal is not bolted to the press or the floor. The two-hand controls for the press are located approximately 13-inches from the die bolster, the point of operation, at the same elevation, with a direct, unobstructed path from the two-hand controls to the point of operation. This distance was so close that Employee #1 inadvertently activated the slide with his elbows and got his left hand caught in the point of operation. Employee #1 sustained a partial amputation to his left index finger and was transported to Citrus Valley Medical Center in Glendora for treatment.

Keywords: DIE, AMPUTATED, FINGER, TWO-HAND CONTROL, CAUGHT BETWEEN, POINT OF OPERATION, PUNCH PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 126090893 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close