Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201796539 - Employee Suffers Amputation Using Press Brake

Accident Summary Nr: 201796539 -- Report ID: 0950644 -- Event Date: 09/27/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30132918110/08/200239990Accutech Mfg

Abstract: At approximately 12:15 p.m. on September 27, 2002, Employee #1, a machine operator, was using the press brake to bend parts. A die was in the middle of the press brake to bend the part in a channel like configuration. The machine was equipped with a two hand control. According to Employee #1, the machine was working normally. Employee #1 would place the part in, press the two hand control to initiate the stroke, and then retrieve the parts with his fingers. Then suddenly at the time of the accident, the machine malfunctioned. It cycled by itself when Employee #1 tried to retrieve the part. Employee #1's hands were not on the controls. Even as the machine was turned off, the machine continued to cycle by itself. After closer examination of the press brake, it was determined that the linkage was not well maintained. Some of the holes for the pins and bolts were elongated. This allowed the linkage to be in a position wherein, it would continue to cycle. Employee #1 suffered three smashed fingers and his middle finger was amputated. Employee #1 was hospitalized.

Keywords: DIE, AMPUTATED, HAND CONTROL, INADEQUATE MAINT, PRESS BRAKE, FINGER, MACHINE OPERATOR, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301329181 Hospitalized injury Amputation Machine operators, not specified

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close