Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201790482 - electric shock - contact with overhead line thru boom

Accident Summary Nr: 201790482 -- Report ID: 0950612 -- Event Date: 11/25/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12558230411/25/199717310Brown & Fesler, Inc.

Abstract: One employee (Employee #1) was driving a company truck while a coworker followed in a Ford truck equipped with an R.O. Stinger crane and digger. The boom was raised approximately 7.3 meters above the ground while the coworker drove the Ford to the next worksite. The coworker noticed that the truck tilted to his right. He stopped the truck, and Employee #1 came back to offer assistance. Employee #1 began to lower an outrigger while the coworker engaged the power take-off. The digger struck an overhead guy at 5.5 meters above the ground, pulling an overhead power line down far enough to contact the guy. This energized the truck at the same time Employee #1's right hand touched a railing on the truck. He was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CRANE BOOM, ELECTROCUTED, E GI IA, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street New project or new addition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125582304 Fatality Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Fencing, installing lights, signs, etc.
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close