Accident Report Detail

Accident Summary Nr: 201780509 - Two Employees Buried When Trench Collapses

Accident Summary Nr: 201780509 -- Report ID: 0935000 -- Event Date: 09/19/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30556527709/20/200216230R. Williams Construction Company

Abstract: At about 7:45 a.m. on September 19, 2002, Employee #1 and Employee #2 were in a trench to clean the water pipes on a pump that was used to remove ground water from the trench. R. Williams Construction was installing underground a 12-inch in diameter sewer line. The trench was about 69-feet long in Class B soil. The trench was about ten-feet deep. At the bottom, the trench was about six-feet wide. From the bottom, the north and south faces were vertical for about five-feet and then sloped at about one-horizontal to one-vertical (45-degrees to the horizontal). Trench shields or shores were not used. A broken PVC pipe protruded from the north face of the trench. Reportedly, this is where the trench face collapsed. This work was part of a $157-million Chumash Casino Project on the Santa Ynez Native American Trust Land. At the time of the accident, large trucks were moving demolition debris on a road near the trench. The trucks reportedly caused the trench walls to slough off dirt and the bottom of the trench to vibrate. Employee #1 died from a fractured skull. It took the fire department about 45-minutes to extricate Employee #2 and about six-hours to remove the Employee #1. Employee #1 died and Employee #2 was hospitalized with a fractured hip.

Keywords: FRACTURE, COLLAPSE, WORK RULES, TRENCH, SKULL, BURIED, CAVE-IN, HIP, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $20,000,000 and over 3 30 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 305565277 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse
2 305565277 Fatality Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.