Accident Summary Nr: 201773405 - Employee Is Killed in Fall Into Machine

Accident Summary Nr: 201773405 -- Report ID: 0213900 -- Event Date: 07/08/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31307421307/08/20092066311320Cocoa Services Lp

Abstract: At approximately 10:30 a.m. on July 8, 2009, Employee #1 and four coworkers were at a 300,000 square foot warehouse used primarily to house cocoa beans. They process raw solid chocolate by melting it and then shipping it out by tanker trucks to the final user. They manually drop chocolate liquor slabs into a melting tank. One employee was on each side of a pallet with a one ton box of chocolate liquor slabs, cakes are 1.5-in. by 12-in. by 18-in. One employee would hand the slabs to the other employees standing adjacent to them who then dropped them into the melting tank through the 26-in. square opening. A fifth worker operated a fork lift and would place the boxes of chocolate on an elevated platform. The platform was 9 ft high and was directly over the two melting tanks. The tanks measure 7.3 ft wide by 7.66 ft high by 15.83 ft long. The bottom of the tank is circular while the top is square. A coworker came up the stairs, removed the platform hatch cover and placed it towards the rear of the platform. He then went to the back of the 24 ft square platform to put on some shoe covers. He saw Employee #1 as he was walking across to his work station just as he stepped into the 26-in. square opening. Employee #1 was possibly struck by a blade of the agitator and swept around the tank one or two times before it was stopped. Employee #1 was killed.

Keywords: ASPHYXIATED, FLOOR HOLE, CAUGHT BETWEEN, FALL, FLOOR OPENING, STRUCK BY, NIP POINT, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 313074213 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close