Accident Summary Nr: 201771698 - Five Employees Burned from Chemical Explosion

Accident Summary Nr: 201771698 -- Report ID: 0213900 -- Event Date: 01/25/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30339463901/25/200233390Hi-Temp Specialty Metals, Inc.

Abstract: A small steel process tank was filled with multiple metal baskets of tantalum capacitors cooked overnight in hot nitric acid. The hot nitric acid was used to remove some of the epoxy resin encapsulant from a tantalum anode. The nitric acid was drained each morning after the capacitors were cooked. The baskets of cooked capacitors were removed and rinsed in water. Mostly tantalum anodes remained. Employee #1 was killed and five other employees were seriously injured as a residue, containing picric acid, exploded, when Employee #1 placed a basket back into the drained tank, presumably to remove more encapsulant. Picric acid (trinitrophenol), and possibly other unstable nitrated compounds, formed in a nitration reaction between nitric acid and the bisphenol moiety of the epoxy resin. These nitrated compounds precipitated out of the nitric acid solution. Over time, as the spent nitric acid was drained from the tank after each batch, the precipitated nitrated compounds would accumulate on the inside surface of the tank. The spent nitric acid was typically used for multiple batches further concentrating unstable nitrated compounds on the tank's surface. Placement of the basket was likely the source of ignition. The explosion was estimated to be of a magnitude similar to an explosion involving more than 5 pounds of trinitrotoluene. The five seriously injured employees were treated for burns and bruises at a local hospital.

Keywords: BURN, EXPLOSION, CHEMICAL REACTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303394639 Fatality Other Laborers, except construction
2 303394639 Hospitalized injury Burn(Chemical) Laborers, except construction
3 303394639 Hospitalized injury Burn(Chemical) Laborers, except construction
4 303394639 Hospitalized injury Burn(Chemical) Laborers, except construction
5 303394639 Hospitalized injury Bruise/Contus/Abras Laborers, except construction
6 303394639 Hospitalized injury Burn/Scald(Heat) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.