Accident Report Detail

Accident Summary Nr: 201762986 - Employee dies in fall accessing scaffold platform

Accident Summary Nr: 201762986 -- Report ID: 0626600 -- Event Date: 09/11/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31136025909/14/20071799237990Infinity Construction Services, Lp

Abstract: At approximately 10:45 a.m. on September 11, 2007, Employee #1, a scaffold builder, and three coworkers were dismantling part of a hanging scaffold built in a pipe rack to install a 3 ft process line at the Exxon Olefins BOP-X plant in Baytown, TX. Employee #1 tied a rope to a truss so that the rope could be used lower the scaffold to the ground after it was disconnected. He then walked 10 ft along the truss to a supported scaffold platform. As he stepped onto the platform, Employee #1 was trying to connect his lanyard to a scaffold runner but he apparently missed the tie-off point with the snap hook. He lost his balance and fell approximately 17 ft onto a road in the plant. Employee #1 sustained blunt force trauma to his head, facial injuries, a fractured rib, and a collapsed lung. He was transported to the hospital, where he died two days later. The employer had a 100 percent tie-off policy, and Employee #1 was wearing a fall protection harness and a shock absorbing Y-lanyard. He had connected the snap hooks together to make a loop on an overhead process line shortly before he fell. Employee #1 apparently disconnected the two ends of the lanyard from one another while he was trying to tie-off to the runner.

Keywords: HEAD, DISMANTLING, WORK RULES, CONSTRUCTION, LANYARD, FALL, FALL PROTECTION, LOST BALANCE, TIE-OFF, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Alteration or rehabilitation $50,000 to $250,000 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311360259 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 17 feet
Cause: Temporary work (buildings, facilities)
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.