Accident Summary Nr: 201762937 - Employee Is Killed in Fall from Platform

Accident Summary Nr: 201762937 -- Report ID: 0626600 -- Event Date: 02/17/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31106377007/09/20075032423320Martin Marietta Materials Southwest, Inc.

Abstract: At approximately 3:00 a.m. on February 17, 2007, Employee #1 and a rail crew operator were working to increase the flow rate of aggregate from a hopper onto a conveyer belt. Employee #1 was trying to turn a four prong wheel handle used to lift the slide gate on the hopper. Employee #1 was unable to move the slide gate by hand, so he placed a 42-in. cheater pipe over one of the four prongs on the wheel handle to gain leverage. As Employee #1 was pulling downward on the cheater pipe, the pipe slipped off the wheel prong and Employee #1 stumbled backward off the working platform and fell 42 in. to the ground. Employee #1 fell into a 24-in. gap between the platform and the wall. Employee #1 landed with his head down and the weight of his body resting upon his head and neck. Employee #1 was killed. The autopsy report identified the cause of death as positional asphyxia.

Keywords: PLATFORM, ASPHYXIATED, CONVEYOR, FALL, LOST BALANCE, HOPPER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311063770 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.