Accident Summary Nr: 201762291 - Employee Dies from Asphyxia When Trench Caves In

Accident Summary Nr: 201762291 -- Report ID: 0626600 -- Event Date: 06/29/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30858718707/01/20051794238910Metro City Construction

Abstract: On June 29, 2005, Employee #1 was working in a trench when it caved in and buried him. The employee died two days later.

Keywords: CHEST, ASPHYXIATED, CONSTRUCTION, TRENCH, CAUGHT BETWEEN, BURIED, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street New project or new addition $5,000,000 to $20,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 308587187 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Backfilling and compacting
Fatality Cause: Collapse of structure

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.