Accident Summary Nr: 201701562 - Employee recieves burns while cleaning potato frying vat

Accident Summary Nr: 201701562 -- Report ID: 1054115 -- Event Date: 07/19/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30659811107/22/20032037311411J R Simplot Company

Abstract: At approximately 3:25 a.m. on July 19, 2003, Employee #1 was attempting to remove partially solidified cooking oil in a potato frying vat by feeding air pressure into the oil drain lines. For some reason, the check valve to the vat, located above him, was left open. This caused the forced air to push the hot, approximately 385 degrees, cooking oil on top of him. Employee #1 was hospitalized and treated for second and third degree burns, covering over 40 percent of his body.

Keywords: BURN, MAINTENANCE, CHECK VALVE, HOT COOKING OIL, PRESSURE PIPING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306598111 Hospitalized injury Burn/Scald(Heat) Roasting and baking machine operators, food

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.