Accident Summary Nr: 201634599 - Employee is burned in vapor explosion

Accident Summary Nr: 201634599 -- Report ID: 1054191 -- Event Date: 08/01/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30782863208/05/20042952324122Herbert Malarkey Roofing Company

Abstract: At approximately 9:30 a.m. on August 1, 2004, Employee #1 was beginning the process of transferring hot asphalt from a blending tank to a holding tank. The blending tank was nearly filled with hot asphalt which was heated to approximately 385 degrees Fahrenheit. Added into the hot asphalt were styrenic block copolymer pellets are which are known to form flammable hydrocarbons in the presence of heat above 250 degrees Fahrenheit. Employee #1 was standing on an enclosed platform above the tanks and was opening a transfer valve. A flash fire occurred in the blending tank, which had a large top hatch with an unlatched door. He was thrown backwards and struck the transfer pipe. Employee #1 was hospitalized with second-degree burns on both forearms and the left side of his face. One possible ignition source was an elevator lift and chute system that was not grounded and bonded. Another possible ignition source was clumps of un-dissolved pellets that were found conglomerated around the elevator chute entry point due to the upper agitator paddle for the blending tank breaking off several days before the explosion. Per the styrenic block copolymer MSDS, the pellets "contain residual unsaturation which can undergo exothermic oxidative degradation. Accumulation of product in areas exposed to elevated temperatures for extended periods in air may result in self-heating and auto-ignition". A third possible ignition source was the tank transfer valve wheel that was being opened by Employee #1 at the time that the fire occurred. One final factor was the blockage of the tank's vent, which was 90-percent plugged with styrenic pellets, reducing the emergency relief capacity.

Keywords: BURN, FLAMMABLE LIQUID, UNSECURED, FIRE, EXPLOSION, HOT ASPHALT, STYRENE, VALVE, FACE, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307828632 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close