Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201634409 - Employee injured while operating metal lathe

Accident Summary Nr: 201634409 -- Report ID: 1054111 -- Event Date: 06/01/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30663369406/02/20043599332710Arthur F Dick Jr

Abstract: On June 1, 2004, Employee #1 was adjusting the diameter of an auger shaft of a metal lathe. Without deenergizing the machine, Employee #1 reached across the top of the rotating auger to adjust the flow of the cutting oil. His right sleeve was unbuttoned, which became caught in the rotating auger and Employee #1 was pulled into the lathe. Employee #1 was hospitalized and treated for a fractured right arm.

Keywords: CLOTHING, FRACTURE, LATHE, ROTATING SHAFT, MACHINE OPERATOR, CAUGHT BY, LOCKOUT, AUGER, ARM

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306633694 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.