Accident Summary Nr: 201621422 - Employee killed in caterpillar overturn

Accident Summary Nr: 201621422 -- Report ID: 1054116 -- Event Date: 09/06/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30632517609/08/20032411113310Hm Inc

Abstract: On September 6, 2003, Employee #1 was operating a Caterpillar D6H bulldozer with grapples mounted on the rear. As he was attempting to repair an area of an old skid road on a steep incline, the tracks removed all of the surface soil exposing a layer of solid rock. The grousers slipped on the rock and the dozer slid off the roadway up against a standing Madrone tree. The employee backed down the bank and attempted to turn around to travel back down the road in the direction that he came from. As he attempted to travel back onto the roadway, the dozer was positioned at least partially sideways on the bank. The employee had the grapples in the full up position and had raised the front blade to allow clearance. The raised attachments changed the dozer's center of gravity. The dozer rolled down the hillside and crossed the logging road. The front blade was torn from the dozer and the employee was ejected just below the logging road. The dozer continued to roll to the bottom of the canyon. The employee was found by a coworker who witnessed a portion of the accident. Employee #1 was pronounced dead on the scene.

Keywords: ROLL-OVER, BULLDOZER, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306325176 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close