Accident: 201620879 - Employee Injured When Struck By Skyline

Accident: 201620879 -- Report ID: 1054116 -- Event Date: 12/03/2001
InspectionOpen DateSICEstablishment Name
30465792712/05/20012411Ngu Logging Inc

The logging crew was "yarder" logging with a motorized carriage using a slack line system of the main line. Employee #1, a choker setter, was pre-setting four chokers. Employee #1 set three chokers while the rigging slinger and other choker setter were rigging another turn. Once the turn was landed and the logs were lying on the landing Employee #1 went under the skyline to set his last choker. When the yarder operator slacked the main line, the carriage drifted down the skyline (malfunctioned carriage brakes on the skyline). The yarder operator hit the foot brake pedal to stop the carriage. When the carriage stopped abruptly it created a whip in the skyline. Employee #1 was under the skyline on a ridge and the skyline was approximately 30 ft to 40 ft above. The whip of the skyline sent the skyline down over Employee #1 and struck him on the top of his hard hat. Employee #1 was driven to the ground due to the impact. Employee #1 was able to get up on his own and walk out of the unit. Once on the landing the "hook tender" made a decision to have the chaser transport Employee #1 to the hospital where he was admitted for diagnostic testing and determined to have fractured and crushed vertebrae. Employee #1 was hospitalized.

Keywords: fracture, head, rigging, hard hat, equipment failure, struck by, sling, logging, vertebra, choker

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 304657927 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close