Accident Summary Nr: 201611449 - Employee injured when struck by flying object

Accident Summary Nr: 201611449 -- Report ID: 1054118 -- Event Date: 04/23/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30267955006/15/199973890The Sheffer Corporation

Abstract: At approximately 5:00 p.m. on April 23, 1999, Employee #1 was pressure testing a hydraulic cylinder that was anchored to a test bench. Employee #1 could not retract the cylinder so he called the manufacturer, who instructed him to loosen the valve with a wrench. As he did, the valve blew out under 3000 psi of pressure. Employee #1 sustained lacerations and broken bones in his hand.

Keywords: FRACTURE, HYDRAULIC CYLINDER, LACERATION, VALVE, STRUCK BY, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302679550 Hospitalized injury Fracture Inspectors, testers and graders

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.