Accident Summary Nr: 201580057 - ELECTRIC SHOCK - EARTH POTENTIAL FROM DOWNED POWER LINE

Accident Summary Nr: 201580057 -- Report ID: 1032300 -- Event Date: 02/11/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30118389302/12/199807830Red Hawk Tree Service Inc.

Abstract: Three employees of a tree service firm were performing a line-clearance operation for a hospital. One employee was using an ax and wedges to fell the trees; another was cutting the felled trees; and the third was stacking the cut trees and branches. The crew was felling a fir tree that they planned to have fall parallel to the 13.8-kilovolt (phase-to-phase) overhead power line. The tree was about 19.8 meters tall and had more branches on the side facing the power line than on the other side. The crew had wedged the tree to fall away from the power line. However, when the employee with the ax made the back cut, he cut through the holding wood; and the tree fell into the power line, knocking all three phase conductors from a utility pole and snapping one. Initially, no one was injured. As the broken conductor arced and bounced around, it struck the chipper and started a fire. The employee who had been cutting the trees ran in front of the truck and received an electric shock from the potential gradient in the earth across his feet. (According to the coroner's report, entry and exit wounds were found on the soles of the employee's feet.) The tree feller made three attempts to pull the injured employee away from the truck where he had fallen, and the feller received electric shocks until he was able to drag the victim clear of the place where the potential gradient was too high. His coworkers administered cardio-pulmonary resuscitation and summoned emergency medical services. Their rescue attempts were to no avail. The injured employee was pronounced dead at the hospital 45 minutes after the accident.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CPR, POTENTIAL GRADIENT, ELECTROCUTED, E PTD, TREE, ELEC UTILITY WORK, TREE TRIMMING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301183893 Fatality Electric Shock Groundskeepers and gardeners, except farm

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close