Accident Report Detail

Accident Summary Nr: 201573326 - Five employees asphyxiated by vapors from chemical fire

Accident Summary Nr: 201573326 -- Report ID: 0830500 -- Event Date: 10/02/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31047003410/02/20071721237310Rpi Coating, Inc.

Abstract: On October 2, 2007, Employees #1 through #5 and four coworkers, of RPI Coating, Inc., were staging materials in a penstock. They were using a Graco Xtreme airless sprayer, which heated a two-part epoxy paint. The sprayer was not operating correctly and the crew was directed to use approximately 5 to 10 gallons of methyl ethyl ketone (MEK) to flush the hoses. The flammable MEK vapors and liquids ignited into a flash fire. The resulting heat could have exceeded the decomposition temperature of the Duromar HPL 2510 hardener, and combustion by-products filled the occupied area of the penstock. The crew attempted to escape to a smoke-free area, but the natural ventilation of the penstock caused the smoke and vapors to enter the area into which they fled. Employees #1 through #5 were exposed to carbon monoxide, carbon dioxide and/or to chemical vapors from the decomposition of the Duromar HPL-2510 hardener and base of the epoxy paint. All five employees dies of asphyxia. There were several potential ignition sources, including: 1) the sprayer's heater, which did not appear to be de-energized prior to the use of MEK; 2) static electricity, with the sprayer recycling MEK into the hopper while the sprayer sat on a rolling scaffold; or 3) the electrical wiring, which did not appear to be approved for use in Class I-Division or Class I-Division 2 locations.

Keywords: ASPHYXIATED, MEK, WORK RULES, FIRE, CONSTRUCTION, INHALATION, SPRAY PAINTING, CHEMICAL VAPOR, TOXIC FUMES, CARBON MONOXIDE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline Maintenance or repair $500,000 to $1,000,000 1 12 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310470034 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor
2 310470034 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor
3 310470034 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor
4 310470034 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor
5 310470034 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Interior painting and decorating
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.