Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201573292 - Employee Is Struck by Flying Object and Is Killed

Accident Summary Nr: 201573292 -- Report ID: 0830500 -- Event Date: 08/19/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31046899608/20/20071389238910Centerfire Trucking

Abstract: Employee #1 was driving a gin pole truck away from oil and gas drilling lease on which an oil and gas drilling rig was being set up. This vehicle was a Kenworth semi-tractor, outfitted with gin pole winch assembly. This semi-tractor was also pulling a flatbed trailer via a fifth-wheel. As Employee #1 departed this lease and began driving down the unpaved service road, at some point in the travel - it appears that the Number 1 winch engaged. This winch is a power-take-off (PTO) and contains wire rope with a snatch block. The block was secured on the rear of the flatbed of the semi-tractor to an anchorage referred to as a "sheep foot". As the truck traveled forward, the PTO engaged the winch which tightened the wire rope and created force on the block pulling it away from the sheep foot. The sheep foot then fractured, releasing the block which flew through the rear window of the truck, striking Employee #1 in the head. Employee #1 suffered a concussion and was killed.

Keywords: GIN POLE, OIL WELL DRILLING, CRUSHED, STRUCK BY, FLYING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310468996 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close