Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201572583 - Employee dies from crushing injuries

Accident Summary Nr: 201572583 -- Report ID: 0830500 -- Event Date: 12/18/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30637559312/23/20031771238110Central Concrete Services, Inc.

Abstract: On December 18, 2003, Employees #1 and another coworker were preparing to utilize a lowboy trailer when Employee #1 was crushed between the lowboy trailer and the rotating superstructure of a Somero-S240 Laser Screed.

Keywords: CONCRETE FORM WORK, CAUGHT BETWEEN, TRAILER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Other $500,000 to $1,000,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 306375593 Fatality Other Truck drivers, heavy Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.