Accident Summary Nr: 201561941 - Employee killed in trench cave-in

Accident Summary Nr: 201561941 -- Report ID: 0854910 -- Event Date: 08/14/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31045685008/16/20071794238910Myton City

Abstract: At approximately 11:30 a.m. on August 14, 2007, Employee #1 and two coworkers were working on a municipal project, installing a new section of sewer pipe to be connected to the city's system. They used a municiapl backhoe to dig a 28 ft long by 6 ft wide by 9 ft deep trench. While one coworker waited with the backhoe, Employee #1 and the other coworker entered the trench, placing a ladder on the east end of the excavation as a means of entrance and exit, as needed. The coworker waited near the ladder, while Employee #1 used a hand shovel to manually grade the trench near the middle. As he was working, the north wall of the trench broke loose, pinning Employee #1 to the opposite side and trapping him waist deep in dirt. Coworkers immediately rushed to his aid, and local volunteer fire department personnel and Duchesne County police officers were called to the scene. It took 25 minutes to remove Employee #1 from the trench. He was transported to the University of Utah Medical Center, where he died on August 16, 2007, of accident-related injuries.

Keywords: EXCAVATION, TRENCH BOX, INSTALLING, PINNED, WORK RULES, CONSTRUCTION, TRENCH, CAVE-IN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310456850 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Site grading and rock removal
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.