Accident Summary Nr: 201520475 - Employee Killed When Bulldozer Rolls Over

Accident Summary Nr: 201520475 -- Report ID: 0111500 -- Event Date: 01/27/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12328511601/27/199915210J.J. Russo & Son Construction Inc.

Abstract: Employee #1 was off-loading a bulldozer from a trailer at a construction site. Employee #1 backed the trailer up to the driveway with the left-side tires up on the curb and the right-side tires on the street. The ramps at the end of the trailer were down, and the machine was running. The bulldozer slid off the right side of the trailer landing on its left side. Employee #1 either fell off or was thrown out of the driver's seat and landed under the front area of the ROPS protection. Employee #1 was killed.

Keywords: ROLL-OVER, ROPS, CONSTRUCTION, CRUSHED, OFF LOADING, BULLDOZER, TRAILER
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $250,000 to $500,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 123285116 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Site grading and rock removal
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.