Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201510526 - Employee's jaw fractured when struck by falling crane boom

Accident Summary Nr: 201510526 -- Report ID: 0950651 -- Event Date: 08/16/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30999409308/16/20071622237990Blue Iron Inc

Abstract: At approximately 10:30 a.m. on August 16, 2007, Employee #1, of Blue Iron, Inc., was disassembling a mobile lattice-boom crane. The crane boom was between 3 ft and 4 ft off the level ground and was supported by pendant cables, which ran from the struts on top of the car body to the end of the boom. Employee #1 was driving out the pins that held the bottom of the crane boom together. He had just driven out the second pin when the crane boom rotated around the two intact upper pins and then fell straight down, striking the right side of his face. Employee #1's jaw was fractured in two places.

Keywords: FRACTURE, DISMANTLING, UNSECURED, CRANE BOOM, MOBILE CRANE, CONSTRUCTION, STRUCK BY, FACE, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $5,000,000 to $20,000,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 309994093 Hospitalized injury Fracture Crane and tower operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close