Accident Summary Nr: 201504909 - Employee Is Killed When Struck by Falling Jib

Accident Summary Nr: 201504909 -- Report ID: 0950614 -- Event Date: 04/06/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30733327804/06/20041731238210Metropolitan Electrical Construction Inc.

Abstract: At approximately 4:00 p.m. on April 6, 2004, Employee #1, a mobile crane operator, was operating a crane at the control panel on the left side of the carrier. A coworker was assisting Employee #1 in storing a jib. Employees were not trained in the work-related tasks. Employee #1 observed the coworker installing the jib stow pin upside down into the jib stow bracket-boom and told him to install it from the top. Employee #1 removed the two pins on the left side jib to boom tip, then jogged the jib to seat it on the front jib stow bracket-boom. He then went to the front of the boom and installed the cable and anti-two block device on the boom tip sheave and reinstalled the load line retaining pins. He elevated the boom, approximate 20 degrees, and began to rewind the cable. The swing jib became displaced from the mounting brackets and fell. Employee #1 ran away from the control area to avoid the falling jib and crossed into its path. He was struck by the jib and died.

Keywords: BOOM, CRANE BOOM, JIB CRANE, CRUSHED, STRUCK BY, CRANE OPERATOR, FALLING OBJECT, UNTRAINED, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Tower, tank, storage elevator Demolition $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307333278 Fatality Other Crane and tower operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Demolition
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.