Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201500949 - EMPLOYEE HOSPITALIZED AFTER INHALING CHLORINE GAS

Accident Summary Nr: 201500949 -- Report ID: 0950614 -- Event Date: 07/22/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
11967514811/20/199851690Holchem Inc.

Abstract: At approximately 3:00 p.m. on July 22, 1998, Employee #1 was assigned to fill two totes (200 and 300 gallons) with sodium hypochlorite solution from the bulk tank (6000 gallon) by the lead warehouseman. Employee #1 initiated filling the totes in the recessed spill collection area ("pit") adjacent to the bulk sodium hypochlorite tank. Employee #1 stated that he filled the smaller tote first, and began filling the second. The bulk tank was emptied to a point where gravity was not sufficient, so the employee the set up of a pump to continue pulling liquid. This was a common procedure. Employee #1 stated that he asked the lead warehouseman or the operations manager if he should use the green pump and the hose lying on the pump located in the warehouse. Employee #1 was given permission to use the "green" pump which was designated for use with sodium hypochlorite solutions. However, the operations manager and lead warehouseman stated Employee #1 set up the yellow pump designated for use with bleach. Employee #1 noted that the pump he pulled had a bleach odor before he connected it to use. Employee #1 did not feel this was unusual, as the pump was used in the morning by a driver to dispense bleach. According to the Employee #1, the two ends of the hose were connected (male to female) and clasped. Employee#1 removed the clasp connecting the ends and attempted to separate the ends by hand but could not. Employee #1 placed the hose under his right arm, and pulled the ends away from each other (female end in left hand). The ends separated and Employee #1 immediately perceived a burning sensation down his throat. Employee #1 stated that he did not feel any spray or wetness, nor did he observe a liquid release, or perceive odors. Employee #1 stated he was not able to breathe or talk, and that he fell to the ground, and continued coughing for approximately 15 minutes. The operations manager discovered Employee #1 when he came out to the pit area from the office to investigate the coughing. There were no other witnesses to the incident. Employee #1 suffered acute toxic inhalation and acute airway edema, and was hospitalized for his injuries.

Keywords: RESPIRATORY, BLEACH, HOSE, CHLORINE, TOXIC FUMES, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119675148 Hospitalized injury Other Freight, stock and material handlers, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close