Accident Summary Nr: 201496809 - Employee Is Killed from Ammonia Release

Accident Summary Nr: 201496809 -- Report ID: 0950625 -- Event Date: 09/11/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31507757809/11/20127361561310Randstad Horizons Dba Placement Pros

Abstract: On September 11, 2012, Employee #1, a temporary employee of Randstad Horizons d/b/a Placement Pros, was working as a racker-blender at Gibson Wine Company, was exposed to anhydrous ammonia, and died of asphyxia. Employee #1 was found in the west hallway 54 ft from the men's restroom. Upon further investigation, a cellar supervisor was to clear iced juice in Chiller 13 by performing a "hot gas" procedure. The evaporator's temperature is raised by opening a bypass valve that equalizes the refrigerant pressure. The cellar supervisor was distracted in conversation with a graveyard shift supervisor and inadvertently opened the dump valve. The dump valve purges excessive oil from the refrigerant system into a barrel of water. The opening of the dump valve instead of the bypass valve caused oil to discharge and liquid ammonia to release forming a gas cloud. The cellar supervisor evacuated the area but left the dump valve open. The gas cloud engulfed the area and was pushed against the building containing two hallways, a men and women's bathroom, and a break room. The gas cloud formation was captured on a surveillance video, but dissipated within seconds. Approximately one minute before the release, Employee #1 entered the west hallway. It was calculated the refrigerant charge at the facility was 23,640 pounds of anhydrous ammonia.

Keywords: LEAK, ASPHYXIATED, INHALATION, GAS, ANHYDROUS AMMONIA, AIR CONTAMINATION, VALVE, PROCESS SAFETY, CHEMICAL, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315077578 Fatality Asphyxia Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close