Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201495835 - Employee Losses Consciousness in Fertilizer Tank

Accident Summary Nr: 201495835 -- Report ID: 0950625 -- Event Date: 07/16/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31507076307/28/20110761115115Pacheco Brothers, Inc.

Abstract: On July 16, 2011, Employee #1, who was employed by a farm labor contractor, was working at the employer's farm field in Tehachapi, CA. Employee #1 was assigned to clean out a 500-gallon fertilizer tank for the employer, so that they could spray the field. Employee #1 climbed inside the tank to unstop it, so that he could rinse it out. He did not check the oxygen level before entering the tank, and he soon passed out. Another employee working nearby saw what happened and extracted Employee #1 from the tank. An ambulance was called and Employee #1 was taken to Kern Medical Center, located in Bakersfield, CA, for treatment. An employer representative reported the incident to Cal/OSHA on July 18, 2011.

Keywords: OXYGEN DEFICIENCY, UNCONSCIOUSNESS, ASPHYXIATED, CONFINED SPACE, AGRICULTURE, TANK CLEANING, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315070763 Non Hospitalized injury Asphyxia Farm workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close