Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201487568 - Employee Is Crushed Between Scissor Lift and Wall

Accident Summary Nr: 201487568 -- Report ID: 0950622 -- Event Date: 02/01/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
12576018103/03/20051751238130Ciarra Construction

Abstract: Employee #1 was clearing an 8 ft by 8 ft wall opening from a scissor lift. The controls malfunctioned, and he was crushed between the top of wall opening and scissor lift guardrail. Employee #1 was admitted to the hospital for treatment of multiple chest contusions.

Keywords: CHEST, WALL, CONTROL LEVER, CONSTRUCTION, CRUSHED, MECH MALFUNCTION, AERIAL LIFT, CONTUSION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125760181 Hospitalized injury Bruise/Contus/Abras Carpenters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Temporary work (buildings, facilities)
Fatality Cause: Crushed/run-over/trapped of operator by operating

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close