Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201483245 - Employee overexposed to antiquing solution

Accident Summary Nr: 201483245 -- Report ID: 0950622 -- Event Date: 03/06/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
12569887803/14/200025140Benicia Foundry & Iron Works

Abstract: Between 7:00 a.m. to 9:00 a.m. on March 6, 2000, Employee #1 became ill while dipped fabricated metal parts into C-22 Antiquing Solution as part of a bronzing process. Chemical constituents of the solution were selenic acid and copper sulfate. Prior to bronzing, the antiquing solution was diluted one-to-one with water in a 5-gallon tub. Employee #1 dipped the parts into the solution and poured the solution over parts he could not fully submerge in the solution. Employee #1 started feeling ill from the very beginning of the dipping work. Employee #1 informed a coworker that he could not continue with the dipping operation because it was making him sick, but coworker instructed him to continue the work. Upon further complaining he was instructed to rest in his car. Employee #1's condition continued to worsen and he was taken to Mt Diablo Hospital where he was admitted with the "Restricted Airways Disease". Employee #1 was hospitalized for 72 hours and provided respiratory therapy and cough medication. A coworker who assisted Employee #1 with the dipping work for approximately one hour also felt ill, but did not seek medical attention. The antiquing solution is a very corrosive chemical and in the form it was used had a pH of 1.9.

Keywords: LUNG, METAL SHOP, CORROSIVE, DIP TANK, CHEMICAL VAPOR, OVEREXPOSURE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 125698878 Hospitalized injury Other Hand molding, casting, and forming occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close