Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201482114 - Two Employees Died From Burns After A Fire At A Refinery

Accident Summary Nr: 201482114 -- Report ID: 0950622 -- Event Date: 02/23/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12565947402/23/199917990Interstate Scaffolding

Abstract: On February 23, 1999, two employees, Employee #1 and Employee #2, died of burns sustained from a fire at Tosco refinery. The fire occurred at the Fractionator tower in the 50 crude oil processing unit at Tosco "Avon" refinery in Martinez, California. Employee #1 and #2 were engaged in a maintenance activity to remove and eventually replace the naphtha draw piping which had developed a leak. Tosco decided to fix the repair while the process unit remained in operation. The highly flammable gasoline-like, benzene-containing hydrocarbon flowed through openings into the line and onto hot surfaces in the operating unit. The naphtha piping ignited, causing a fire near the bottom of the tower, which continued to spread up and down the tower. The fire killed two workers and seriously injuring another contractor. The contractor was hired by Tosco to erect scaffold for the removal and replacement of the naphtha piping. Three additional contractor employees also assisted Tosco maintenance employees while the pipeline was being cut. Employee #1 and #2 died of burns sustained during the fire. They were unable to escape. The surviving contractor employee had been sent to another assignment and location in the refinery after lunch when the fire occurred. Investigators determined that Tosco failed to isolate or to drain the naphtha piping from the operating process prior to cutting into the line.

Keywords: BURN, FIRE, REFINERY
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery Maintenance or repair $50,000 to $250,000 100 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 125659474 Fatality Burn/Scald(Heat) Supervisors; carpenters and related workers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior carpentry
Fatality Cause: Fire/explosion
2 125659474 Fatality Burn/Scald(Heat) Carpenters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior carpentry
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.