Accident Report Detail
Accident Summary Nr: 201482015 - Employee struck by bar joist
Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
---|---|---|---|---|
125838367 | 04/29/1999 | 1791 | 0 | Kse, Inc. |
Abstract: On December 9, 1998, Employee #1, an iron worker for a structural steel erector working at a movie theater construction site, was struck by one of four bar joists (approximately 50 ft long by 2 ft tall) that fell about 30 ft from the roof installation. The joists, about 6-ft center, did not have bridging installed between them to resist the lateral movement caused by a load was placed on them by a crane. This oversight caused the joists to tip and fall when two bundles of decking were placed upon them. Employee #1 was hospitalized for his injuries.
End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
---|---|---|---|---|---|---|---|
Commercial building | New project or new addition | $250,000 to $500,000 | 1 |
Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
---|---|---|---|---|---|---|---|
1 | 125838367 | Hospitalized injury | Fracture | Structural metal workers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Other Activities-Installing Ornamental And Archite Fatality Cause: Struck by falling object/projectile |