Accident Summary Nr: 201450681 - Employee Is Killed from Electrocution, Crane Contacts Line

Accident Summary Nr: 201450681 -- Report ID: 0418500 -- Event Date: 08/09/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30111765108/10/20051799238990Bulldog Office Contractors, Inc.

Abstract: On August 9, 2005, Employee #1 and coworkers were lifting a double-wide mobile trailer with a truck crane. Six house cables, which were attached to the underside of a spreader bar, were lowered down from the top of the trailer so that three of the cables hung down on each side. They pulled the three cables hanging down on the north side of the trailer underneath and attached metal beckets to shorter cables hanging down from the spreader bar on the opposite side. This procedure formed a wire cradle underneath the belly of the trailer. During the lift of the trailer, Employee #1 and five coworkers were stationed around the sides. Employee #1 was holding a house cable in place over a small piece of pipe softener along the bottom edge of the I-beams. The rigging came within 10 ft of a power line and a wire rope lifting sling contacted the 48-kilovolt, 3-phase power line. Employee #1 was electrocuted.

Keywords: WIRE ROPE, TRUCK CRANE, ELECTROCUTED, ELECTRIC SHOCK, SLING, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301117651 Fatality Electric Shock Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Temporary work (buildings, facilities)
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.