Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201408325 - Employee Is Struck by Vehicle

Accident Summary Nr: 201408325 -- Report ID: 0552651 -- Event Date: 11/29/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31327333611/30/20101629237990Up Engineering & Architectural Inc

Abstract: Employee was measuring sewer pipe from top of manhole and was struck by vehicle.

Keywords: SEWER, VEHICLE, STRUCK BY, MANHOLE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant Other $50,000 to $250,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 313273336 Fatality Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Surveying
Fatality Cause: Crushed/run-over by highway vehicle

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close