Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201401999 - Two Employees Injured in Truss Collapse

Accident Summary Nr: 201401999 -- Report ID: 0552651 -- Event Date: 07/14/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
12710672207/17/199815410Holt Builders

Abstract: Employees were setting 50 foot roof trusses with improper temporary bracing. The trusses collapsed causing Employee #1 and Employee #2 to fall 12 feet to the ground. Employee #1 sustained a fracture to the chest and Employee #2 sustained a fractured leg. Two plumbers working below also were injured by the trusses collapsing.

Keywords: CHEST, FRACTURE, TRUSS, ROOF, COLLAPSE, FALL, BRACING, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $500,000 to $1,000,000 1

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 127106722 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior carpentry
Fatality Cause: Other
2 127106722 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior carpentry
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close