Accident Summary Nr: 201392826 - Overhead Crane's Lift Bolt Breaks, Falling Load Kills Worker

Accident Summary Nr: 201392826 -- Report ID: 0552652 -- Event Date: 03/21/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31541242903/21/20133089326199Mollertech Llc

Abstract: On March 21, 2013, Employee #1, a 39-year-old male with Mollertech LLC, was using an overhead crane to move injection die from storage area using wrong size lift bolt. Lift bolt failed causing the suspended die to fall. The falling die struck Employee #1 and another stored die on the floor. Employee #1 was killed in the event.

Keywords: CRANE HOOK, SUSPENDED LOAD, CRUSHED, BOLT, OVERHEAD CRANE, CRANE BLOCK, CRANE OPERATOR, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315412429 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.