Accident Summary Nr: 201361839 - Employee electrocuted while installing HVAC duct work

Accident Summary Nr: 201361839 -- Report ID: 0419400 -- Event Date: 09/23/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30431551809/25/200217110Central Heating And Air Conditioning Of Grenada

Abstract: On September 23, 2002, Employee #1 and a coworker were installing two HVAC systems in the attic of a house that had been constructed in 1904. The electrical system of the house consisted of knob and tube and wiring dating from the 1950s, with a large number of uninsulated connections. Employee #1 was installing aluminized insulation around the duct work and system plenums when a section of the insulation contacted one of the uninsulated connections. This energized the ducting and he was electrocuted. When rescuers tried to remove Employee #1 from the attic, they moved a section of the insulation and were also shocked when another part of the duct work became energized. The system was then completely disabled.

Keywords: DUCT, INSTALLING, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, ELECTRICAL WORK, ELEC CIRC PART--MISC, ELECTRIC CONDUCTOR
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Alteration or rehabilitation $50,000 to $250,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304315518 Fatality Electric Shock Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Electrocution by touching exposed wire/source

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.