Accident Summary Nr: 201360625 - Seven employees overcome by toxic gas

Accident Summary Nr: 201360625 -- Report ID: 0419400 -- Event Date: 09/17/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30103690109/17/199820770Protein Products, Inc.

Abstract: On September 17, 1998, several employees were retrieving and repairing a chain in a pit that contained water and inedible catfish parts. Employee #1 was exiting the pit when he fell back into the pit. Employee #2 was holding Employee #1's head to keep it above the material in the pit when he collapsed. Employee #3 and Employee #4 attempted to enter the pit, but were unable to do so. Both Employees #3 and #4 collapsed outside of the pit. Employee #5 attempted to enter the pit, but was unable to do so, and collapsed outside the pit. Employee #6 entered the pit and collapsed inside the pit. Employee #6 was rescued by Employee #7. Employee #1 was asphyxiated by hydrogen sulfide gas and died. Employees #2, #6 and #7 were admitted to the hospital. Employees #3, #4 and #5 were not hospitalized. The inspection indicated that permit-required confined space procedures were not followed; an entry permit was not completed, atmospheric testing not performed, retrieval equipment was not available, and personal protective equipment was not utilized.

Keywords: ASPHYXIATED, ENTRY PERMIT, CONFINED SPACE, HYDROGEN SULFIDE, TOXIC ATMOSPHERE, INHALATION, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301036901 Non Hospitalized injury Asphyxia Occupation not reported
2 301036901 Non Hospitalized injury Asphyxia Occupation not reported
3 301036901 Non Hospitalized injury Asphyxia Occupation not reported
4 301036901 Hospitalized injury Asphyxia Occupation not reported
5 301036901 Fatality Asphyxia Occupation not reported
6 301036901 Hospitalized injury Asphyxia Occupation not reported
7 301036901 Hospitalized injury Strain/Sprain Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.