Accident Report Detail

Accident Summary Nr: 201353612 - Employee Is Killed When Struck by Mortar Bucket

Accident Summary Nr: 201353612 -- Report ID: 0419700 -- Event Date: 07/10/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31181804107/10/20081541236220Greenhut Construction Company, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31181805807/10/20081742238310Gulf Coast Specialities
Inspection NrDate OpenedSICNAICSEstablishment Name
31181806607/10/20081731238210Sanders Brothers Electric
Inspection NrDate OpenedSICNAICSEstablishment Name
31181808207/10/20081542236220W.R. Johnson, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31181809007/10/20081793238150Lee'S Glass & Window Works, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31181810807/10/20083446332323Brownsville Ornamental Iron Works, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31181643307/10/20081741238140Miguel Angel Marcelo Martinez
Inspection NrDate OpenedSICNAICSEstablishment Name
31181807407/10/20081623237110B & H Contracting, Inc.

Abstract: On July 9, 2008, Employee #1 was standing on the top portion of the outriggers of the tubular welded scaffold. He was waiting for the operator to bring a grout hog bucket, called a mortar bucket, to fill the concrete wall. The operator of the JCB variable reach forklift, Serial Number SLP508C05E0588187, Model Number 508C, was hoisting the grout hog bucket to Employee #1. The grout hog bucket was not secured to the forks by the safety pin. The bucket slipped off the forks and struck Employee #1's head. He was killed.

Keywords: STRUCK BY, FALLING OBJECT, TUBULAR SCAFFOLD, HEAD, WALL, UNSECURED, SLIP, CONCRETE, OUTRIGGER, CRUSHED
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $500,000 to $1,000,000 15 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311818041 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
2 311818058 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
3 311818066 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
4 311818082 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
5 311818090 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
6 311818108 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
7 311816433 Fatality Fracture Brickmasons and stonemasons Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Exterior masonry
Fatality Cause: Struck by falling object/projectile
8 311818074 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.