Accident Summary Nr: 201351350 - Electric Shock - Direct Contact with Overhead Line

Accident Summary Nr: 201351350 -- Report ID: 0419700 -- Event Date: 01/30/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30398305001/30/200107830Asplundh Tree Expert Co.

Abstract: A line-clearance tree trimmer was working with a ground worker and a supervisor, performing a line-clearance tree trimming operation. At about 10:25 am, the crew went to a new area. The tree trimmer parked his aerial lift truck below a 13-kilovolt overhead power line, and the supervisor parked his truck behind the aerial lift truck. The supervisor and ground worker placed traffic cones. Then, the ground worker started the auxiliary motor powering the aerial lift and outriggers. He lowered the outrigger on the passenger side of the truck, and the supervisor lowered the outrigger on the driver's side. The tree trimmer climbed into the aerial lift bucket and began elevating it. The supervisor went to fill a chainsaw with gasoline and did not watch the tree trimmer. The ground worker stood about 1 meter from the passenger-side outrigger and watched the tree trimmer. The tree trimmer was facing the aerial lift controls without watching the overhead power line, which was located behind him. He contacted the phase conductor with his head as his lower back contacted the neutral conductor. The ground worker warned the tree trimmer just before he contacted the power line, but it was too late. The tree trimmer was electrocuted. The tree trimmer and ground worker had not been fully trained regarding their respective job assignments. Additionally, the supervisor did not conduct a job briefing for the new location.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E PTD, TREE TRIMMING, AERIAL LIFT, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303983050 Fatality Electric Shock Forestry workers, except logging

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close