Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201350196 - Two employees killed in explosion

Accident Summary Nr: 201350196 -- Report ID: 0419700 -- Event Date: 11/14/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
30101776011/15/199628990Mei Holdings Inc Dba Martin Electronics Inc

Abstract: A granulator operator and a granulator operator trainee were loading dry composition consisting of magnesium, butadiene-acrylonitrile dry rubber, acetone, polytetrafluoroethylene, and methyl ethyl ketone into a granulator machine. The employees' normal duties consisted of transporting the composition to a processing building with a battery-operated golf cart and a small trailer. They would then hand carry the composition inside to be loaded into the granulator machine. After the operator and trainee left the building, the control room operator would activate the granulator remotely from another building and monitor the operation by closed-circuit television. On completion of the granulation process, the granulator operator and trainee would reenter the building, unload the finished product, and take it outside to the trailer. The process would be repeated until all of the material was processed. Normally, there would have been only a single employee performing the duties of a granulator operator. However, a new granulator operator was being trained. At one point during the operation, the granulator operator was inside the building loading composition into the granulator, and the trainee was taking a container of granulated composition back to the trailer. The trainee was outside the building. An explosion occurred, demolishing the building and fatally injuring the granulator operator and the trainee. The granulator operator died from central nervous system traumatic injuries, and the trainee died of exsanguination due to bilateral hemothoraces. The explosion was likely caused either by a discharge of static electricity or by the accidental activation of the granulator machine by the control room operator. The employees had been working with the combustible materials wearing excessively worn protective clothing and without required protective gloves.

Keywords: FRACTURE, STATIC ELECTRICITY, ASPHYXIATED, E GI IV, ELECTRICAL, INTERLOCK, LOCKOUT, EXPLOSION, COMBUSTIBLE DUST

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301017760 Fatality Fracture Occupation not reported
2 301017760 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close