Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201344769 - One Employee Dies, Another Is Injured in Pipe Line Explosion

Accident Summary Nr: 201344769 -- Report ID: 0729700 -- Event Date: 08/28/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31179248509/10/20081389213112United Service Limited

Abstract: At approximately 4:00 p.m. on August 28, 2008, Employees #1 and #2 and a coworker were working on a 2.375-in. crude oil flow line from a horsehead well to the tank battery. They dug a trench to access the leaking flow line and cut out a 6-ft long section using a cold cutter. Employee #1 and Employee #2 attempted to thread the cut on flow line with a manual pipe threader but the dies on the threader were dull. They asked the office to have new dies delivered for the pipe threader. While waiting, both employees and the coworker left the location with the trench open and pipe ends open. The employees went to another location to repair a poly pipe and returned to the first location two hours later. Employee #1 and Employee #2 installed the new dies in the Rigid electric pipe threader instead of the manual pipe threader they had used earlier. Employee #2 got in the trench with the electric pipe threader and started to expose piping when the trench was engulfed in flames. Employee #1 jumped out and rolled to put out the flames and Employee #2 ran about 50 yards to cattle and jumped in the water. At that time Employee #1 and Employee #2 caught fire, coworker was preparing the replacement. The coworker attempted to put the fire with fire extinguishers. The coworker discharged two PKP fire extinguishers. The coworker then drove the two employees to Beaver County Memorial Hospital about 20 minutes away. The Beaver County Memorial Hospital then transferred Employee #1 and Employee #2 to Via Christi St. Francis Hospital in W Kansas. Employee #1 and Employee #2 were hospitalized for second and third degree burns to their arms, neck and faces. Employee #1 died September 1, 2008. Employee #2 was hospitalized for his burns and released at a later date. After release, Employee #2 received more care to treat the burns as an outpatient.

Keywords: BURN, FIRE, TRENCH, CRUDE OIL, EXPLOSION, PIPELINE, NECK, OIL WELL SERVICING, ARM, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311792485 Fatality Burn/Scald(Heat) Drillers, oil well
2 311792485 Hospitalized injury Burn/Scald(Heat) Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.