Accident Summary Nr: 201344694 - Employee Is Killed When Struck on Head by Drilling Cap

Accident Summary Nr: 201344694 -- Report ID: 0729700 -- Event Date: 03/26/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31178744403/27/20081381213111Murfin Drilling Company, Inc.

Abstract: At 7:28 p.m. on March 26, 2008, Employee #1 was working with three other employees of his crew, along with an employee of Trilobite Testing, Inc., performing a wet stem test at the drill site. After several attempts were made to stretch and secure the rubber pull back sling on the drilling head to the wet cap with no success, Employee #1 went to assist in attaching the pull back sling to the drilling head block. The driller was operating the winch when the Trilobite Testing employee directed the driller to keep the drilling heads/bales down on drilling floor. While the tester was in the doghouse, without being directed, the driller raised the drilling bails to the top of the derrick. The derrick hand gave the high sign to the driller that it was ready to be spun out and removed. The driller started the winch, and the wet cap was spun out. The tension on the rubber pull back sling was strong, and wet cap was thrown out at a tremendous force. By the time the derrick employee saw what was happening and alerted the crew on rig floor, it had already struck Employee #1 in the head. Employee #1 was wearing a hard hat, gloves, and safety boots. There were three eyewitnesses to the accident. Employee #1 was transported to Great Bend Hospital, where Employee #1 was pronounced dead by an Emergency Room doctor.

Keywords: HEAD, OIL WELL DRILLING, DRILL COLLAR, STRUCK BY, CONCUSSION, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311787444 Fatality Concussion Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close