Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201321189 - Employee Dies from Chemical Poisoning

Accident Summary Nr: 201321189 -- Report ID: 0317900 -- Event Date: 01/04/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31126652201/07/20082899325998Gelest Inc.

Abstract: On January 4, 2008, Employee #1 was preparing to distill tri-methyl silyl diazo-methane mixed with di-ethyl ether. The container he was pouring the mixture from or the funnel he was using slipped, and the amount of 300 ml to 400 ml of chemical spilled. Employee #1 sustained some splatter from the chemical. He cleaned it up, washed, and changed his clothing. Then, Employee #1 finished his shift. Later that night, Employee #1 died at the hospital.

Keywords: SLIP, CHEMICAL REACTION, SPILL, CHEMICAL VAPOR, POISONING, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311266522 Fatality Poisoning(Systemic) Chemists, except biochemists

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close