Accident Summary Nr: 201312204 - Employee Caught Between Forklift and Storage Rack Dies

Accident Summary Nr: 201312204 -- Report ID: 0213400 -- Event Date: 12/14/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31564218101/04/20122844325611Chanel, Inc.

Abstract: On December 14, 2011, Employee #1, with Chanel, Inc., was attempting to move a pallet of glass bottles into the staging area. Employee #1 was pinned between the horizontal rack beam (crossbeam) of the storage rack and his forklift. Employee #1 sustained fractures, and ultimately, he died from his injuries.

Keywords: PINNED, CAUGHT BETWEEN, INDUSTRIAL TRUCK, PALLET, STORAGE RACK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 315642181 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.